3.1 Test equipment
The shear tests of bolted rock joints are primarily used to study the shear mechanical properties and resistance mechanism of the bolt. The shear test types mainly include single and double rock joint shear tests (Zhang, Xu, et al., 2022). The principle of the two test methods is the same. Both test methods make shear dislocation deformation of jointed rock mass samples by applied shear loads, and the anchorage shear performance of the bolt is studied by monitoring the data of shear force and shear displacement. Figure 3a shows the schematic diagram of the single joint shear test. The sample mainly comprises two rock masses, and the operation is simple. The anchorage shear test can be conducted under varying normal stresses and anchoring angles. However, the single shear test generally has a low shear load and small shear displacement, so it can only complete the small-scale shear test, and the failure displacement of the bolt may not be achieved. In addition, the shear friction between the joint surfaces cannot be eliminated, and the pure shear state of the bolt cannot be attained. Figure 3b illustrates the double-joint shear test. The double-joint shear sample comprises three rocks with two symmetric shear planes; the engineering scale bolt can be carried out, and the prestress can be applied at both ends of the bolt. In addition, the shear friction of the joint surface can be eliminated by setting gaps between rock samples, but applying normal stress in the double shear test is challenging. Based on these two anchoring shear test principles, many bolt shear test equipment has been continuously developed and improved, and representative relevant shear equipment is presented as follows.
Shear test principle diagram of anchorage joint. (a) Single rock joint shear test and (b) double rock joint shear test.
3.1.1 Single shear test device
Table 1 is a summary of the single shear test device. The principle of the single joint plane shear test is the same as that of the conventional direct shear test, so the conventional direct shear device can be used to study the shear performance of bolted rock joints (He et al., 2022, 2023; Liu & Li, 2018; Zhang & Liu, 2014). With further development, the design of single shear test factors and variables of bolted joints becomes more complex and difficult. Jiang et al. (2004) and Thirukumaran and Indraratna (2016) found that the normal stress on deep rock mass changes constantly with shear displacement, which is more consistent with the boundary condition of constant normal stiffness (CNS) than with constant normal loading (CNL). Therefore, MIS-233-1-55-03 shear equipment capable of carrying out constant normal stiffness loading has been developed. A comparative study was conducted on shear tests of bolted joints under CNL and CNS boundary conditions (Jiang et al., 2021). To meet the shear test requirements under conditions of medium and high strain rates, a large-scale rock mass dynamic performance test system was developed by Qi et al. (2020), and the bolted shear tests under conditions of different loading rates were conducted (Luo et al., 2023).
Table 1. Summary of the single shear test device.
| No. |
Test device picture |
Equipment parameter |
Functional evaluation |
Reference |
| 1 |
 |
RMT-301 rock mechanics loading test system Maximum normal load: 1500 kN Maximum tangential load: 500 kN Sample size: 100–200 mm cube Maximum stroke of vertical and horizontal: 50 mm |
It can meet the basic test requirements of small-scale anchor bolt shear under quasi-static conditions, cannot apply prestress, and has small shear displacement. |
Liu and Li (2018) |
| 2 |
 |
JAW-600 rock shear seepage testing machine Maximum vertical load: 600 kN Maximum horizontal load: 600 kN Maximum stroke: 25 mm Sample size: 200 mm × 100 mm × 100 mm Loading speed: 0.01–100.00 mm/min |
Wang et al. (2018); Zhang et al. (2022) |
| 3 |
 |
Large-scale rock mass dynamic performance test system Maximum vertical load: 500 kN Maximum horizontal load: 1000 kN Maximum sample size: 1000 mm × 200 mm Loading speed: 0.001–1000 mm/s |
Can satisfy the anchorage shear test loading of small-scale bolts under quasi-static and medium and high strain rate conditions. |
Qi et al. (2020) |
| 4 |
 |
MIS-233-1-55-03 shear instrument Maximum vertical load: 200 kN Maximum horizontal load: 200 kN Sample size: 200 mm × 100 mm × 100 mm |
Can satisfy the anchorage shear test load of the small-scale bolt under constant normal stiffness and constant normal strength. |
Jiang et al. (2004) |
| 5 |
 |
SINTEF/NTNU anchor test device Maximum axial load: 500 kN Maximum tangential load: 600 kN Sample size: two cubes with a side length of 0.95 m |
It has the functions of full-size bolt independent drawing, independent shear and tensile shear coupling test, but the friction between the sample and the equipment frame is large during loading, and the normal stress cannot be applied. |
Chen (2014); Stjern (1995) |
| 6 |
 |
Central South University bolt tensile shear comprehensive test equipment Maximum axial load: 500 kN Maximum tangential load: 600 kN Sample size: two cubes with a side length of 1 m |
The roller design reduces the friction between the sample and the equipment frame, can meet the basic test requirements of full-size anchor shear under quasi-static conditions, and cannot apply normal stress. |
Chen et al. (2020) |
| 7 |
 |
Indian Institute of Technology large-scale direct shear test system Maximum vertical load: 1500 kN Maximum horizontal load: 2000 kN Sample size: two 75 cm × 75 cm × 90 cm blocks |
Large group anchor shear tests can be carried out, and prestress cannot be applied. |
Srivastava et al. (2015) |
| 8 |
 |
MISSR single shear device Maximum shear load: 1200 kN A single cylindrical specimen has a diameter of 25 cm and a length of 1.8 m. |
A single shear test of bolt and cable with a maximum anchor length of 3.6 m can be carried out, and prestress cannot be applied. |
Aziz et al. (2018) |
| 9 |
 |
The State Key Laboratory of Efficient Coal Mining and Clean Utilization Testing equipment for comprehensive mechanical properties of rock bolt Maximum axial load: 610 kN Maximum tangential load: 1100 kN Sample size: The diameter of the specimen is 12 cm, and the length is 1 m |
It has the functions of independent stretching, torsion, bending, shearing, and impact, but it does not have the function of pure shear strength test of prestressed anchor bolts. |
Kang et al. (2020) |
Due to the limitations of sample size, equipment load, and shear displacement, conventional direct shear equipment can only carry out the anchorage shear test of small-scale bolts. To address this issue, the test device dedicated to the shear performance of full-size bolts has been improved and developed. The SINTEF/NTNU bolt test device developed by SINTEF in 1995 in Trondheim, Norway, and the Rock Mechanics Laboratory of the Norwegian University of Science and Technology is the most representative full-size tensile-shear comprehensive test device, which has the functions of full-size bolt pulling, shearing, and tensile shear coupling test. Nevertheless, the friction between the sample and the equipment frame is significant. In 2020, a new bolt tension and shear comprehensive test device was designed by Central South University in China based on the SINTEF/NTNU bolt test device to reduce the friction between concrete specimens and rigid frame, but the device could not apply normal stresses (Chen et al., 2020). In 2015, the servo-controlled large-size direct shear test device was developed by the Indian Institute of Technology to carry out the group anchor test and large-scale anchorage shear test. The device could increase the loading performance and the size of the shear box. The shear force applied by the servo-controlled hydraulic jack could reach 2000 kN, and the maximum normal force could reach 1500 kN, satisfying the anchoring shear test under the condition of a single anchor or group anchor of a full-size bolt (Srivastava & Singh, 2015). A single shear device named “MISSR” was developed by Megabolt Company in Australia in 2018 to test the shear performance of a longer-length bolt or anchor cable. The device comprised two 90 cm cylindrical specimens connected by a 1200 kN press, and the single shear test on bolts and cables with anchor lengths up to 3.6 m could be carried out (Aziz et al., 2018). In 2020, the State Key Laboratory of Efficient Coal Mining and Clean Utilization in China successfully developed a new comprehensive mechanical properties test device. The device has independent functions of stretching, twisting, bending, shearing, and impact, and each functional module can be combined. The device can test the longest anchorage length of 1.2 m. However, a high strain rate test cannot be performed on it (Kang et al., 2020).
3.1.2 Double shear test device
Table 2 is the summary table of the double shear test device. Aziz et al. (2016) developed a double shear device for small-size bolts, which adopted a universal testing machine as the shear load-applying unit. However, the size range of the device for testing bolts was minimal, and it was not suitable for testing large-size bolts and higher loads. Craig and Aziz (2010) scaled up the initial device, developed the MKII double shear device, and replaced the small universal testing machine with a large press because of the small size of the test piece and the limited output shear load of the small universal testing machine. However, it was difficult to test the pure shear strength of prestressed anchor bolts due to the high friction caused by the close contact between specimens. Aziz et al. (2016) further improved the MKII double shear device by equipping it with an independent axial rigid frame to provide transverse support and avoid close contact between concrete specimens during the prestress shear process of the bolt, thus blocking the transfer of prestress between specimens and eliminating the friction generated by the shear surface. Imperial College London (Grasselli, 2005), China General Institute of Coal Research (Li, 2019), and China University of Mining and Technology-Beijing (Tong et al., 2023) have also developed and produced double shear test devices, whose loading function, test principle, size, and load are similar to the MKII double shear device. Li, Hagan, et al. (2019) changed the central shear load unit of the conventional double shear device from a press to an impact hammer to develop a double impact shear device with a maximum theoretical impact energy of 5.439 kJ (185 kg × 9.8 m/s2 × 3 m) to realize the double shear test of anchor rod under impact load. With a maximum impact speed of 7.67 m/s, the device can test up to 0.9 m anchorage length bolts; however, compared with the loading requirement of higher strain rate, it cannot be achieved at present.
Table 2. Summary of the double shear test device.
| No. |
Test device picture |
Equipment parameter |
Functional evaluation |
Reference |
| 1 |
 |
British Imperial College bolt double shear device The size of a single concrete specimen is 60 cm × 60 cm × 100 cm. |
Not suitable for large-size bolts and high test loads. |
Grasselli (2005) |
| 2 |
 |
Wollongong University MKII double shear device Maximum length of specimen: 105 cm Specimen size at both ends: 30 cm × 30 cm × 30 cm Middle specimen size: 30 cm × 30 cm × 45 cm |
The shear surface produces a higher friction force when the specimens are in close contact after prestressing. |
Craig and Aziz (2010) |
| 3 |
 |
Wollongong University small bolt double shear device Maximum length of specimen: 60 cm Specimen size at both ends: 15 cm × 15 cm × 15 cm Middle specimen size: 15 cm × 15 cm × 45 cm |
Not suitable for large-size bolts and high test loads. |
Aziz et al. (2016) |
| 4 |
 |
Wollongong University MKIII double shear device Maximum length of specimen: 105 cm Specimen size at both ends: 30 cm × 30 cm × 30 cm Middle specimen size: 30 cm × 30 cm × 45 cm |
An independent axial rigid frame and transverse support are set up to eliminate the friction generated by the shear surface during prestressed loading. |
Aziz et al. (2016) |
| 5 |
 |
China University of Mining and Technology-Beijing bolt double shear device Maximum shear load: 6000 kN Maximum shear displacement: 250 mm Maximum tensile load: 1200 kN Maximum tensile displacement: 200 mm Single concrete specimen size: 300 mm × 300 mm × 300 mm |
The double shear test on full-size bolts can consider the combined loading of prestress and axial force of the bolt, and the normal stress cannot be applied. |
Tong et al. (2023) |
| 6 |
 |
Bolt impact double shear device Maximum theoretical impact energy: 5.439 kJ (185 kg × 9.8 m/s2 × 3 m) Maximum impact speed: 7.67 m/s Single concrete specimen size: 30 cm × 30 cm × 20 cm |
Impact loads can be applied. |
Li, Hagan, et al. (2019) |
| 7 |
 |
HiBay laboratory, Faculty of Engineering and Information Sciences, University of Wollongong, dynamic shear device Maximum theoretical impact energy: 23.2 kJ (592 kg × 9.8 m/s2 × 4 m) Maximum impact speed: 8.85 m/s Single concrete specimen size: 30 cm × 30 cm × 20 cm |
Impact loads can be applied. |
Khaleghparast et al. (2023) |
Overall, the shear test device of anchored rock joints is gradually improved in terms of loading function, meeting the test requirements of greater shear load, shear displacement, and sample volume. So the shear test for rock mass with anchored joints can be well completed under conventional test variable conditions. However, the collaborative coupling function of multiple loading conditions still needs to be further improved, which cannot meet the loading requirements of complex situations. For example, the application of normal stress on the sample often causes the unloading of the prestress of the bolt, so the two cannot be applied simultaneously, and the intelligent operation and refinement level of the device must be further improved. Also, most of the devices can only complete the shear loading under a quasi-static or low strain rate state, and hence, the anchoring punch shear test devices of high strain rate and ultrahigh strain rate still need to be further developed.
3.2 Test variable analysis
Many factors affect the shear properties of bolted rock joints, such as the geometrical and mechanical parameters of rock mass, bolt, and structural plane. Based on the indoor anchorage shear test, researchers have carried out a lot of research on the test variables (Table 3), such as the strength of rock specimen, the type of bolt, the anchoring angle, and the roughness of the joint surface.
Table 3. Shear test statistics of bolted rock joints.
| Experiment type |
Sample size (mm) (length × width × height) |
Host rock type |
Bolt type/Bolt diameter |
Main content |
Reference |
| SS |
/ |
Granite |
Full-length bonded bolt |
Bolting angles |
Bjurstrom (1974) |
| SS |
/ |
Gypsum, basalt |
Rebar bolts |
Bolting angles |
Dight (1982) |
| SS |
/ |
Limestone, schist |
Resin-grouted bolt |
Surrounding rock strength, bolting angles |
Ansell (2005); Haas (1976) |
| SS |
150 × 150 × 130 220 × 200 × 150 |
Granite, concrete, sandstone |
Rebar bolts/8, 10 mm |
Strength of surrounding rock, diameter of anchor bolt |
Spang and Egger (1990) |
| SS |
300 × 400 × 800 |
Concrete, granite |
Rebar bolts/8, 12 mm |
Bolt strength, bolt diameter, strength of surrounding rock |
Ferrero (1995) |
| DS |
600 × 150 × 150 |
Concrete |
AX, AXR, JAB bolt/24 mm |
Concrete strength, prestress |
Ansell (2005); Aziz et al. (2003) |
| DS |
180 × 60 × 100 |
Concrete |
Swellex bolt/16, 20 mm |
Bolting angles, bolt types |
Grasselli (2005) |
| DS |
600 × 150 × 150 |
Concrete |
Rebar bolts/24.7 mm |
Bolt profile, surrounding rock strength |
Jalalifar et al. (2006) |
| SS |
950 × 950 × 950 |
Concrete |
Rebar bolts, D-Bolts/20 mm |
Anchoring angle, bolt type, strength of surrounding rock |
Chen and Li (2015); Chen (2014) |
| SS |
750 × 750 × 900 |
Concrete |
Fully grouted passive bolts/10 mm |
Normal stress, bolt number |
Srivastava and Singh (2015) |
| DS |
150 × 150 × 450 300 × 300 × 1050 |
Concrete |
Fiber glass bolts, rock bolts, cable bolts |
Bolt type, bolt diameter, prestress |
Li et al. (2016) |
| SS |
100 × 200 × 90 |
Rock-like materials |
S45C steel/3 mm |
Joint roughness |
Wu et al. (2017) |
| DS |
250 in diameter, 900 in length |
Concrete |
Fully encapsulated cable bolts/30 mm |
Cable diameter, cable geometry, prestress |
Aziz et al. (2018) |
| SS |
150 × 150 × 150 |
Concrete |
HRB400/4 mm |
Joint roughness |
Chen et al. (2018) |
| DS |
200 × 100 × 100 |
Rock-like materials |
Anchor bolt/10 mm |
Joint roughness, bolt elongation |
Wang et al. (2018) |
| SS |
100 × 200 × 100 |
Rock-like material |
Rebar bolts/6 mm |
Cyclic loading, joint roughness |
Wu, Jiang, Wang et al. (2019) |
| SS |
400 × 400 × 400 |
Concrete |
8, 12 mm |
Bolting angles, grout strengths, shear loads, bolt diameter |
Li and Liu (2019) |
| DS |
300 × 300 × 200 |
Concrete |
Rock Bolts/8, 16 mm |
Dynamic loading |
Li, Hagan, et al. (2019) |
| SS |
100 × 100 × 100 |
Rock-like material |
HRB400 rebar/6 mm |
CNL and CNS conditions, bolt inclination angle |
Cui et al. (2020) |
| DS |
900 × 150 × 150 |
Concrete |
HRB500 steel, CRM700 steel/13 mm |
Dynamic loading, Pretension |
Shan, Bao, et al. (2021) |
| SS |
100 × 100 × 200 |
Rock-like material |
thread bar/6 mm |
Non-persistent joints |
Zhang, Jiang, et al. (2022) |
| SS |
150 × 150 × 120 |
Rock-like material |
#11 wire/3 mm |
Bolt number, grouting state of the joint, bolt inclination angle |
Lin et al. (2022) |
| SS |
150 × 150 × 150 |
Concrete |
HRB400/10 mm |
Bolting angles, bolt number, bolt spacing |
Liu et al. (2022) |
| DS |
100 × 100 × 100 |
Rock-like materials |
China DIN 975 steel/10 mm |
Prestress, connectivity rates of joints |
Ding et al. (2022) |
| SS |
150 × 150 × 150 |
Granite, marble, sandstone |
NPR steel, Q235 steel/8 mm |
Surrounding rock strength, bolt type, normal stress |
He et al. (2022) |
| SS |
700 × 700 × 1400 |
Concrete |
1860 anchor cable/15.2 mm |
Prestress |
Wang et al. (2023) |
| DS |
300 × 150 × 150 |
Concrete |
Ribbed bolt, smooth bolt/18 mm |
Tendon type, pretension, drop height |
Khaleghparast et al. (2023) |
| SS |
150 × 150 × 150 |
Marble |
NPR steel, Q235 steel, #45 steel/8 mm |
Bolt type, normal stress |
He et al. (2023) |
| SS |
150 × 150 × 150 |
Granite |
NPR steel, HRB400e steel/8 mm |
Shear rates |
Luo et al. (2023) |
| DS |
300 × 300 × 300 |
Concrete |
Anchor cable/21.6 mm |
C-Shaped Tube, Preload |
Shan et al. (2021, 2022); Tong et al. (2023) |
| SS |
200 × 100 × 100 |
Rock-like materials |
Carbon steel/6 mm |
Bolted mode |
Jiang et al. (2024) |
| SS |
100 × 100 × 50 |
Red sandstone, black sandstone, green sandstone, white sandstone, coal |
8.8-grade carbon steel/6 mm |
Anisotropic rock joint |
Jiang et al. (2024) |
| SS |
200 × 100 × 100 |
Rock-Like Materials |
6061–T6 aluminum rod/6 mm |
JRC, anchorage depth |
Han et al. (2024) |
3.2.1 Strength of rock specimen
The mechanical properties of rock mass vary significantly in geotechnical engineering under different working conditions, considerably impacting the performance of bolt support. Representative samples of soft and hard rock jointed rock have been used to conduct laboratory tests to study the shear strength contribution and deformation and instability characteristics of bolts under different rock strength conditions. Spang and Egger (1990) used red sandstone, concrete, and granite to experimentally study the influence of surrounding rock strength on the shear performance of anchorage and showed that the shear contribution of the bolt in soft rock is greater than that in hard rock under the same conditions. Ferrero (1995) showed that the higher the strength and stiffness of the surrounding rock, the more beneficial the play of the shear effect of the bolt. Jalalifar et al. (2006) studied the load transfer mechanism and mechanical properties of rock mass with varying strengths under different prestressed forces through indoor double shear tests and confirmed that rock mass strength and prestressed magnitude greatly influence the shear resistance of joint surfaces, shear displacement, and failure characteristics. Zhang and Liu (2012, 2014) also validated that rock mass strength significantly influences the yield form of the bolt. Bolts generally produce bending yield in soft rocks, whereas tensile shear yield occurs in hard rocks. Chen (2014) found that the yielding speed of the bolt is faster in hard rock. Liu and Li (2018) used white sandstone, marble, and granite as the representatives of soft, medium-hard, and hard rocks, respectively, to conduct anchorage shear tests and proved that the higher the strength of rock mass, the greater the improvement in the shear resistance to the rock joints, and the better the reinforcing effect. He et al. (2023) experimentally investigated the influence of surrounding rock strength on the anchorage shear resistance of 2G-NPR bolt and found that the failure displacement and shear absorption energy effect of the bolt decreased with the increased strength of the surrounding rock (Figure 4). Under the lower strength of the surrounding rock, the bolt would yield at the plastic hinge and then produce tensile bending failure. As the strength of the surrounding rock increases, the bolt is transformed into tension shear failure (Figure 5).
Results of 2G-NPR bolt shear test under different rock strength conditions. (a) Red sandstone, (b) marble, and (c) granite (He et al.,
2022).
Schematic diagram of rock bolt deformation and failure under different surrounding rock strength conditions (He et al.,
2022).
The research studies show that the strength of surrounding rocks significantly influences the shear contribution and the deformation and failure characteristics of the bolts. The shear strength of the joint of the high-strength surrounding rock is better than that of the low-strength surrounding rock, but the rock bolts often exhibit better deformation in the low-strength surrounding rocks. Tensile-shear yield and tensile-shear failure mainly occur when the high-strength surrounding rock is anchored by a bolt, while tensile-bend yield and tensile-bend failure often occur in the low-strength surrounding rock. However, there is no unified understanding of the critical quantitative criteria of tensile shear and tensile bend modes. In addition, the strength of the surrounding rock and the mechanical properties of the anchor bolt should be relative. The same kind of bolt may show tensile bending or tensile shear deformation and failure characteristics under varying strengths of rock mass. Also, the same strength rock mass may cause different deformation and failure characteristics for bolts having different mechanical properties. Therefore, the synergistic relationship between the strength of the surrounding rock and the shear performance of the anchor bolt should be fully considered in the study of the strength of the surrounding rock, and the coupling evaluation criteria of the strength of the surrounding rock and the performance of the bolt should be established.
3.2.2 Joint surface roughness
The dilatancy effect of varying roughness and the wear, climb, and nibbling of the joint surface during shearing affect the anchorage shear resistance of the bolt. Wu et al. (2017) showed that the bolt has a good inhibition effect on the dilatancy of joint planes through a comparative study of shear tests of rock mass with and without anchorage. Chen et al. (2018) studied the influence of joint surface roughness on the deformation characteristics of bolts and demonstrated that the length of the transverse shear deformation section of the bolt gradually increased with the increased joint surface roughness (Figure 6). Zhang (2020) argued that with the increased joint roughness, the peak shear strength and residual shear strength of bolted joints increase to varying degrees. Wang et al. (2021) explored the influence of JRC values on the deformation mechanical properties of the bolt and found that the dilatation effect of rough joint surface can increase the axial deformation ability and axial force of the bolt and change the failure mode of the bolt from tensile shear to tensile bending.
Test results of anchoring joints under different joint roughness conditions. (a) Scanning map of joint surfaces with different roughness, (b) deformation characteristics of the bolt, and (c) shear force–shear displacement curves (Chen et al.,
2018).
The tests were primarily carried out to study the shear performance of anchored rough-jointed rock mass with the same wall strength. In practical engineering, the soft interbedded geological structures are widely distributed, and researchers call this kind of joint with different wall strengths a heterotropic joint or soft and hard interbedded joint. Shear tests on anisotropic joints show that the shear properties of the anisotropic structural plane are more similar to those of the side of the rock mass with relatively weak strength (Mouzannar et al., 2017; Renaud et al., 2021). Jia (2021) carried out anchorage shear tests on jointed rock mass with varying wall strengths and showed that the side with lower strength has a greater degree of failure. Also, the wall strength ratio affects the characteristics of anchorage shear curves and crack development. Gao et al. (2023) believe that the shear strength of anchored jointed rock mass increases with weak sidewall strength.
The literature review presented earlier shows that the dilatancy effect not only directly affects the shear strength of the joint surface but also affects the mechanical properties of anchored joints because the dilatancy angle changes the relative displacement of the joint surface during the shear process. The larger the dilatancy angle, the smaller the deflection of the bolt relative to its axial deformation, that is, the weaker the “pin effect” of the bolt and the greater the effect of the tensile performance of the bolt. However, at present, the evaluation of the shear strength of the anchor rough joint is usually only qualitative, and the quantitative expression of the shear strength and roughness morphology of the anchor roughness joint and the parameters of the bolt still need to be further studied.
3.2.3 Bolt type
Various bolts have been successfully developed for engineering construction and resource exploitation, considering the supporting effect, economic benefit, engineering conditions, and other factors. The double shear test of a full-length bonded bolt and expansion hollow bolt was carried out by Grasselli et al. (1999, 2005). When the shear displacement was small, the contribution of the full-length bonded bolt to the shear strength of the rock joint reached 75% of its ultimate tensile strength, whereas that of the expansion hollow bolt was only 20%. When the bolt fails, the contribution of the full-length bonded bolt to the shear strength of the joint surface can reach 85%–95% of its ultimate tensile strength, whereas the expansion hollow bolt is only 65%–75%. Chen and Li (2015) comprehensively studied the mechanical behavior of full-length bonded bolts and D-type energy-absorbing bolts under tensile shear load, and the results showed that D-type bolt has a broader range of plastic deformation segments and substantial deformation and damage resistance. Li et al. (2016) evaluated the shear performance of rock mass anchored by glass fiber bolt, steel rebar bolt, and ordinary anchor cable by double shear test. It was shown that steel rebar bolts made the most significant contribution to the shear strength, while glass fiber bolts used for temporary support exhibited the least effect. A tension and compression composite energy absorbing bolt (TCC bolt) was developed by Wu, Jiang, et al. (2019), which demonstrated a large deformation performance through structural design, while the anchorage shear test results showed significantly improved shear performance than ordinary bolts. Zhang, Jiang, et al. (2022) conducted a comparative study on the shear performance of a new energy-absorbing bolt and an ordinary rigid bolt under joint cracks of different shapes. The results showed that the shear performance of a new type of bolt was greatly affected by the crack angle and crack shape in the rock mass. The new bolt had a better inhibition effect on shear deformation and dilatation of the jointed rock mass than that of an ordinary bolt. Zhang, Wang, et al. (2022) compared the shear properties of basalt fiber reinforced polymer (BFRP) and traditional reinforcement anchorage joints and found that the shear stiffness of BFRP bolt at the elastic stage was lower than that of conventional reinforcement bolts, yet the peak shear displacement was larger and the residual shear strength was higher. He et al. (2023) conducted indoor shear tests on rock mass anchored by 2G-NPR steel under different normal stress conditions. Q235 steel and #45 steel, two representative common anchor steels, were set as the control group (Figure 7). 2G-NPR steel did not exhibit fracture failure under large transverse shear deformation, whereas Q235 steel and #45 steel had fracture failure under small deformations. The equivalent cohesion, internal friction angle, and shear strength of the rock joints showed the greatest improvement of 2G-NPR steel and had super energy absorption characteristics.
Comparative test study on anchorage shear of Q235 steel, 45# steel, and 2G-NPR steel. (a) Q235 steel, (b) #45 steel, and (c) 2G-NPR steel (He et al.,
2023).
The research studies presented above show that the bolt material properties can significantly affect the shear resistance of the anchorage joint. Also, developing high-strength and high-ductility bolts can substantially improve the shear strength and shear displacement of rock joints. However, the shear resistance properties and mechanical mechanism of the new bolt under complex conditions still need to be further studied. In addition, since research on the shear performance of different types of bolts is often carried out using various test methods under different test conditions, it is impossible to make a quantitative comparison between the shear performance of bolts. Therefore, a unified shear test method and quantitative evaluation criteria for the anchorage joints of bolts should be established.
3.2.4 Anchorage angle
The anchoring angle is the angle between the bolt layout angle and the joint plane. In engineering practice, the anchoring angle is the angle between the bolt and the horizontal plane. Bjurstrom (1974) performed shear tests on bolted granite jointed rock mass, demonstrating that the anchoring angle significantly influences the strength of the “pin effect” exerted by the bolts. When the anchoring angle is below 35°, the bolts mainly suffer tensile failure, while the transverse shear effect is negligible. Dight (1982) showed that the inclined bolt arrangement could attain higher joint plane shear stiffness than the vertical arrangement. Haas (1976) and Ansell (2005) also found the same phenomena and conclusions through shear tests on limestone and schist anchorage at varying angles. Ge and Liu (1988) analyzed the influence of anchoring angles on the shear performance of concrete test blocks with through joints. The results showed that the bolt had a good toughening and cracking arresting effect; also, the shear performance was enhanced the most when the anchoring angle was 60°; 45°–75° was the optimal installation angle. Liu et al. (2017) and Li (2019) examined the influence of anchoring angle under different joint friction angles, confirming that the bending deformation angle and transverse deformation length of the bolt under tensile-shear condition increase with the anchoring angle. Also, when the anchoring angle is smaller than the joint friction angle, the “pin effect” of the bolt can be ignored, and the transverse shear resistance is zero. Li et al. (2021) verified that the anchorage angle and shear direction significantly affect the shear resistance of the bolt. In actual engineering, the installation angle of the bolt should be below 90°, and there is an optimal installation angle. Liu et al. (2022) conducted the double shear test to compare the shear strength under different anchoring angles, and the results showed that the shear strength of the anchoring joint was the largest when the anchoring angle was 60°. In addition, the anchoring angle also had a certain influence on the failure mode of the bolt. When the anchoring angle is small, the bolt exhibits tension shear failure; when the anchoring angle is large, the bolt has tension bending failure.
Based on the previous findings, it is concluded that the anchorage angle significantly influences the shear resistance, especially the “pin effect.” Also, the deformation and failure characteristics of the bolt (tensile-shear failure, tensile-bending failure, and tensile failure) are closely related to the anchoring angle. There is an optimal anchoring angle for bolt anchoring. Still, there is no unified understanding of the quantification criteria of the optimal anchoring angle, which is generally believed to be between 30° and 60° (Figures 8 and 9).
Anchorage joint test results of the bolt under varying anchoring angles (Li,
2019). (a) Photos of the deformation results of the bolt and (b) shear displacement-shear force curves.
PFC numerical simulation results of bolt anchoring shear. (a) Fracture development of surrounding rock, (b) displacement field of anchored rock, and (c) force chain characteristics before and after anchoring (Chen et al.,
2022).
3.2.5 Other test parameters
The anchoring type can be classified as prestressed active support and non-prestressed passive support based on whether the prestressing is applied or not, and full-length anchorage and end anchorage according to its anchoring length. Based on double shear tests, Jalalifar et al. (2006) found that the strength of rock mass and prestress greatly influence the shear resistance of the joint surface, shear displacement, and the failure characteristics. Wang et al. (2016) confirmed that prestressed anchorage significantly improved the shear resistance and shear stiffness of the initial section of the shear-displacement curve and made the final section of the curve exhibit plastic strengthening. Zhang (2010) proved that prestress has a certain effect on the tangential stiffness and peak shear strength of anchored joints through shear tests with or without prestress. Teng et al. (2017, 2018) used 45# steel and preset concrete blocks to conduct shear tests, proving that the full-length anchorage specimen can withstand greater shear force, and the bolt resistance increases faster. Chen (2019) conducted a study on the mechanical properties of rock samples with discontinuous joints and proved that full-length anchoring can significantly improve the mechanical properties of anchoring, and its peak strength and elastic modulus both increase.
Researchers have also studied the effects of load type, bolt diameter, grouting strength, and joint penetration. Spang and Egger (1990) experimentally investigated the influence of bolt diameters on the shear properties of anchorage and showed that the contribution of the bolt to the shear properties of the shear joint plane is proportional to the cross-sectional area of the bolt. Wu, Jiang, Gong et al. (2019) studied the failure characteristics of bolts and the reinforcement effect of jointed rock mass under cyclic shear load, indicating that the shear effect of bolts is greatly affected by cyclic displacement. Cui et al. (2020) carried out shear tests under CNL and CNS boundary conditions and studied the influence of different normal boundary conditions on the shear performance of anchored jointed rock mass. The joint surface failure phenomenon is more severe in the shear process of anchored rock mass under CNS conditions. Zhang, Jiang et al. (2022) studied the anchorage shear properties of non-penetrating joints and found that the joint penetration degree could significantly affect the shear strength and shear displacement of anchorage. The anchorage action of the bolt could also substantially reduce the shear damage of rock mass. With the decrease in joint penetration, bolt resistance to shear deformation decreased.